"The
use of vegetable oils for
engine fuels may seem
insignificant today. But
such oils may become in the
course of time as important
as the petroleum and coal
tar products of the present
time"
Rudolf Diesel, 1912 |

|
|
Basic Features: |
|
Application |
BioDiesel
Purification |
|
Polymer
Structure |
Gel polystyrene
cross linked with
divinylbenzene |
|
Appearance |
Hard Spherical
beads |
|
Functional Group |
Sulfonic Acid |
|
Ionic form as
shipped |
|
|
|

|
|
Product Data: |
|
Moisture
Retention |
H+ |
50 - 60 % |
|
Specific Gravity |
|
1.20 g/ml |
|
Shipping Weight
(approx.) |
|
800 - 830 g/l |
|
Shipping Weight
(approx.) |
|
50 - 52 lbs/ft3 |
|
Temp Limit
(Stability) |
|
150 °C |
|
Temp Limit
(Stability) |
|
300 °F
|
|
|
Purolite
PD206 |
50
Pound Box
Shipping Is Not
Included |
|
$545.50 |
|
|
250
Pound Drum
Shipping Is Not
Included |
|
$2,535.50 |
|
|
B-60
Purolite Ion Filter
The Purolite filter that can go with the
B-60 Filter screens, housing
Specifications:
Capacity 1 pound ion
exchange resin
Flow rate:
0.5 GPM
B-60 Purolite Filter
Free Shipping within US
|

|
ORDER TODAY! |
|
|
|
Purolite Ion Filter
$189.00
(Free Shipping In US)
PayPal |
|
B-150
Purolite Ion Filter
The Purolite filter that can go with the
B-150 Filter screens, housing
Specifications:
Capacity 2 pound ion
exchange resin
Flow rate:
0.5 GPM
B-150 Purolite Filter
Free Shipping within US
|

|
ORDER TODAY! |
|
|
|
Purolite Ion Filter
$389.00
(Free Shipping In US)
PayPal |
|
|
B-150 Purolite Ion Tower
Features:
The Purolite filter kit that can go with
the B-150
comes with 100 Micron
Sock Filter, Assembly materials, PVC
Pluming,
PVC
ball valves, Couplers, Bushings,
Unions, Barbed Nipples, housing,
assembly instructions & Phone
Support.
Mounting Hardware
Not Included
|
|
 |
|
Specifications:
PVC tower - 3 BV
Capacity 10 pounds ion exchange
resin
Flow rate:
2.5
GPM
45" Tall x 6" Wide
|
|
Free Shipping within US |
(Purolite Sold Separately)
|
|
|
|
|
ORDER TODAY! |
|
|
B-150 Ion Towers
$599.00
(Free Shipping In US)
PayPal
|
|
|
B-500 Purolite Ion Tower
Features:
The Purolite filter kit that can go with
the B-500
comes
with 100 Micron Sock Filter, Assembly materials, PVC Pluming, PVC
ball valves, Couplers, Bushings,
Unions, Barbed Nipples, housing, assembly instructions
& Phone Support.
Mounting Hardware
Not Included
|
|

|
|
Specifications:
PVC tower - 3 BV
Capacity 20 pounds ion exchange
resin
Flow rate:
2.5
GPM
70" Tall x 6" Wide
|
|
|
|
|
|
|
ORDER TODAY! |
|
|
B-500 Ion Tower
$699.00
(Free Shipping In US)
PayPal |
|
PUROLITE CONTINUOUS
BATCH TOWERS |
   |
|
Features:
HDP Tower has
Lifetime
Warranty
Purolite Support Bed, Flow-head Assembly, Steal
Pluming, 5.5 GPM Biodiesel Pump,
Couplers, Bushings, Unions, Nipples, Brass Ball Valve,
Assembly materials, assembly
instructions & Phone Support.
:Demotions:
89" Tall x 30" Wide
Specifications:
Capacity 750 pounds ion
exchange resin
Flow rate:
5.5 GPM
|
 |
|
|
 |
Biodiesel Purification Adsorbent
Purolite is good for
300
gallons of Biodiesel flow thru
per pound. If rinsed with methanol every
45
gallons of flow thru per
pound you can get
600
gallons of flow thru per pound
and that methanol can be used for the next batch
This media may replace magnesium
silicate “wash” and water wash.
Purolite is good for 300
gallons of Biodiesel flow thru
per pound. If rinsed with
methanol every 45 gallons of
flow thru per pound you
can get 600 gallons of flow thru
per pound and that
methanol can be used for the
next batch
No
Wet Wash Aids Needed
Ion exchange polishing
systems consist of 1 resin
vessel operating at 0.5 gpm.
This vessel is design based on a
maximum flow of 3 bed volumes
(BV) per hour (dry volume) for
our single vessel. Therefore if
the volume of dry resin would
equals 10 gallons in one vessel,
30 BV equals 30 gallons Maximum
flow is now 30 gallons divided
by 60 minutes per hour or 0.5
gpm (not 0.5 gpm times the
number of vessels). If variable
flows are expected or expansion
is an option multiple trains
operated in parallel should be
considered. Vessels are designed
so that the aspect ratio will be
approximately 3:1 with the
height of the vessel being 3
times the diameter. Linear flow
is approximately 0.5-
gpm ft- 1 - 2 (2.5 - 4.9 m h-1)
vessel surface area.
PUROLITE®
PD206 is a dry polishing media
specifically formulated for
removing by-products remaining
after transesterification to
produce Biodiesel.
PUROLITE® PD206 is
designed for use in
“purification” vessels installed
after phase separation. Point of
use can either be before
demethylation to remove catalyst
and glycerin and prevent back
reactions or after demethylation
as a “final” polishing step.

Once PUROLITE®
PD206 is ready for disposal,
it should be disposed of in
approved landfills or
facilities according to
local regulations. Check
with your local
waste management company for
proper disposal
instructions.
|
PUROLITE®
PD206 improves plant
productivity and lowers
operation costs while enabling
ASTM or EN specifications for
B100 to be achieved.
PUROLITE® PD206
has a long life before
exhaustion. This life is
dependent upon the point of
installation in the
Biodiesel process and on the
level of impurities in the
untreated Biodiesel.
PUROLITE® PD206
functions both as a
dehydrating (desiccant)
media and as an ion exchange
polishing media.
As a desiccant PUROLITE®
PD206 has a high loading
capacity to absorb free
glycerin. Trace methanol and
water although being
absorbed to a limited degree
can be removed by stripping
in the demethylation column.
Additionally the exceptional
exchange capacity removes
residual catalyst, and salts
that remains after phase
separation.
PUROLITE®
PD206 is flow able both in
the dry form and when
exhausted, making it easy to
handle during installation
and removal from
“purification” vessels.
PUROLITE®
PD206 is fully compatible
for use in methyl ester and
ethyl ester purification
processes.
PUROLITE® PD206 can
be washed with methanol on
site several time to
maintain it's ability to
remove glycerin. However it
must be ionically
regenerated to maintain the
ability to remove trace
catalyst and soaps. Consult
your Purolite representative
for availability and
details.
The actual life of
PUROLITE® PD206
will vary depending on
process designs and
operating characteristic of
methyl ester feed quality.
|
|